FY18 ASC P&EM L2 Milestone 6356: Improve Replication of In-service Mechanical Environments. Executive Summary

Technical Report ·
DOI:https://doi.org/10.2172/1760402· OSTI ID:1760402
 [1]
  1. Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
The overall goal of this work was to improve the modeling of laboratory shock and vibration testing. Laboratory shock and vibration testing is used to qualify Nuclear Weapon components for the environment they will experience in the field. Standard practice is to use rigid test fixtures so that no spurious modes are introduced during laboratory testing. Rigid test fixtures may however in some cases change the dynamics of the component being tested, resulting in laboratory testing being more severe than what would occur in the field. This milestone investigated the use of topology optimization to create laboratory test fixtures that would better replicate the dynamics that components experience in field environments.
Research Organization:
Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA)
DOE Contract Number:
AC04-94AL85000; NA0003525
OSTI ID:
1760402
Report Number(s):
SAND--2018-10676R; 668398
Country of Publication:
United States
Language:
English

Similar Records

FY18 ASC P&EM L2 Milestone 6356: Improve Replication of In-service Mechanical Environments
Technical Report · Thu Sep 06 00:00:00 EDT 2018 · OSTI ID:1471972

Improve Replication of In-service Mechanical Environments
Technical Report · Sat Sep 01 00:00:00 EDT 2018 · OSTI ID:1493833

L2 Milestone: Simulations as Data. Quantum Molecular Dynamics Contribution
Technical Report · Mon Sep 10 20:00:00 EDT 2012 · OSTI ID:1051092

Related Subjects