- Institut des NanoSciences de Paris (France)
In this paper, we determine with improved accuracy the complex index of refraction n = 1 - δ + iβ of sputtered chromium thin films for photon energies ranging from 25 eV to 813 eV. These data include the first absolute measurements of the absorption fine structure near the Cr-L edge. First, we verified by combining Rutherford Backscattering Spectrometry and grazing-incidence x-ray reflectometry that the sputtered thin films were pure Cr with a density consistent with tabulated values. Then, we demonstrated that the Cr surface oxide layer remains stable when the samples are exposed to air for up to 4 years. The Cr absorption coefficient β was determined from the transmittance of freestanding Cr thin films with various thicknesses, measured at the ALS synchrotron radiation source. A model is proposed to correct the transmittance data from the spectral contamination of the source. Finally, we used the new β values, combined with theoretical and tabulated data from the literature, in order to calculate the δ values by the Kramers-Kronig relation. The improvement in the accuracy of β values is demonstrated by the f-sum rule. Finally, an additional validation of the new Cr optical constants (δ, β) is performed by comparing the simulated and experimental reflectance of a Cr/B4C multilayer mirror near the Cr-L2,3 edge.
- Research Organization:
- Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States); Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States)
- Sponsoring Organization:
- USDOE National Nuclear Security Administration (NNSA); USDOE Office of Science (SC)
- Grant/Contract Number:
- AC02-05CH11231; AC52-07NA27344
- OSTI ID:
- 1482536
- Alternate ID(s):
- OSTI ID: 1527275
- Report Number(s):
- LLNL-JRNL--768637; ark:/13030/qt0b28x4nt
- Journal Information:
- Journal of Applied Physics, Journal Name: Journal of Applied Physics Journal Issue: 3 Vol. 124; ISSN 0021-8979
- Publisher:
- American Institute of Physics (AIP)Copyright Statement
- Country of Publication:
- United States
- Language:
- English
Optical constants of magnetron sputtered Pt thin films with improved accuracy in the N- and O-electronic shell absorption regions
|
journal | February 2019 |
Optical constants of sputtered beryllium thin films determined from photoabsorption measurements in the spectral range 20.4–250 eV
|
journal | January 2020 |
Similar Records
Optical constants of magnetron sputtered aluminum in the range 17–1300 eV with improved accuracy and ultrahigh resolution in the L absorption edge region
Cr/B4C multilayer mirrors: Study of interfaces and X-ray reflectance
Measurements of the optical constants of scandium in the 50-1300eV range.
Journal Article
·
Tue Nov 19 19:00:00 EST 2024
· Journal of Applied Physics
·
OSTI ID:2481489
Cr/B4C multilayer mirrors: Study of interfaces and X-ray reflectance
Journal Article
·
Wed Mar 23 20:00:00 EDT 2016
· Journal of Applied Physics
·
OSTI ID:1260484
Measurements of the optical constants of scandium in the 50-1300eV range.
Conference
·
Sun Oct 03 00:00:00 EDT 2004
·
OSTI ID:891335