The North American Josephson Voltage Interlaboratory Comparison
Journal Article
·
· IEEE Transactions on Instrumentation and Measurement
- Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
- National Inst. of Standards and Technology (NIST), Gaithersburg, MD (United States)
- Bionetics Corporation, Patrick Air Force Base, Brevard County, FL (United States)
- Fluke Corporation, Everett, WA (United States)
The ninth North American Josephson voltage standard (JVS) interlaboratory comparison (ILC) at 10 V was completed in 2011. An on-site comparison was conducted between the National Institute of Standards and Technology compact JVS and the pivot laboratory system. A set of four traveling Zener voltage standards was then shipped from the pivot laboratory to the other participants. Here, we give the results from the 2011 ILC and review recent comparisons which have used the same traveling standards and similar procedures.
- Research Organization:
- Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
- Sponsoring Organization:
- USDOE National Nuclear Security Administration (NNSA); Fluke Corporation, Everett, WA (United States); High Precision Devices Inc, Boulder, CO (United States)
- DOE Contract Number:
- AC04-94AL85000
- OSTI ID:
- 1426916
- Report Number(s):
- SAND2012--4967J; 498345
- Journal Information:
- IEEE Transactions on Instrumentation and Measurement, Journal Name: IEEE Transactions on Instrumentation and Measurement Journal Issue: 6 Vol. 62; ISSN 0018-9456
- Publisher:
- IEEE
- Country of Publication:
- United States
- Language:
- English
Similar Records
Report of multijunction thermal convertor interlaboratory comparison study for measurements at Sandia National Laboratory.
Comparisons of 10 V Josephson array voltage standards between the BNM/LCIE and the BIPM
Monitoring industrial voltage standards by transporting Zener references calibrated by ETL Josephson standard
Technical Report
·
Wed Jul 01 00:00:00 EDT 2009
·
OSTI ID:985497
Comparisons of 10 V Josephson array voltage standards between the BNM/LCIE and the BIPM
Conference
·
Fri Dec 30 23:00:00 EST 1994
·
OSTI ID:125686
Monitoring industrial voltage standards by transporting Zener references calibrated by ETL Josephson standard
Conference
·
Fri Dec 30 23:00:00 EST 1994
·
OSTI ID:125668