Comparisons of 10 V Josephson array voltage standards between the BNM/LCIE and the BIPM
Conference
·
OSTI ID:125686
- BNM/LCIE, Fontenay-Aux-Roses (France)
- BIPM, Sevres (France)
An indirect comparison between the 10 V Josephson array voltage standards of the BNM/LCIE and the BIPM has been carried out using Zener-diode based voltage references as transfer standards. The results show an agreement of 5 parts in 10{sup 9} with an uncertainty (1{sigma}) of 3 parts in 10{sup 9}, mainly due to instability of the Zener references. A direct comparison is to be carried out early in 1994 to avoid this limitation.
- OSTI ID:
- 125686
- Report Number(s):
- CONF-940603-; TRN: 95:005769-0053
- Resource Relation:
- Conference: CPEM `94: conference on precision electromagnetic measurements, Boulder, CO (United States), 27 Jun - 1 Jul 1994; Other Information: PBD: 1994; Related Information: Is Part Of 1994 Conference on precision electromagnetic measurements digest; DeWeese, E.; Bennett, G. [eds.]; PB: 577 p.
- Country of Publication:
- United States
- Language:
- English
Similar Records
Comparison of quantum Hall effect resistance standards of the BNM/LCIE and the BIPM
The new BIPM 1-V reference standard based on an array of Josephson junctions
Intercomparisons of Josephson array voltage standards: Euromet project 199
Conference
·
Sat Dec 31 00:00:00 EST 1994
·
OSTI ID:125686
+1 more
The new BIPM 1-V reference standard based on an array of Josephson junctions
Journal Article
·
Fri Dec 01 00:00:00 EST 1989
· IEEE Transactions on Instrumentation and Measurement (Institute of Electrical and Electronics Engineers); (USA)
·
OSTI ID:125686
Intercomparisons of Josephson array voltage standards: Euromet project 199
Conference
·
Sat Dec 31 00:00:00 EST 1994
·
OSTI ID:125686