Comparisons of 10 V Josephson array voltage standards between the BNM/LCIE and the BIPM

Conference ·
OSTI ID:125686
;  [1];  [2]
  1. BNM/LCIE, Fontenay-Aux-Roses (France)
  2. BIPM, Sevres (France)

An indirect comparison between the 10 V Josephson array voltage standards of the BNM/LCIE and the BIPM has been carried out using Zener-diode based voltage references as transfer standards. The results show an agreement of 5 parts in 10{sup 9} with an uncertainty (1{sigma}) of 3 parts in 10{sup 9}, mainly due to instability of the Zener references. A direct comparison is to be carried out early in 1994 to avoid this limitation.

OSTI ID:
125686
Report Number(s):
CONF-940603--
Country of Publication:
United States
Language:
English

Similar Records

Comparison of quantum Hall effect resistance standards of the BNM/LCIE and the BIPM