Report of multijunction thermal convertor interlaboratory comparison study for measurements at Sandia National Laboratory.
Two Multijunction Thermal Voltage Converters (MJTCs) were provided to the Sandia National Laboratory Primary Standards Laboratory (Sandia PSL) as part of an interlaboratory comparison (ILC). This report summarizes the results of the measurements of the devices (S 127D1 and S 127C2) measured at Sandia PSL from March 4 to March 15, 2009. The SNL/NM portion of an interlaboratory comparison of multijunction thermal convertors was successfully completed with a demonstrated measurement uncertainty of 60ppm (k=2).
- Research Organization:
- Sandia National Laboratories (SNL), Albuquerque, NM, and Livermore, CA (United States)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC04-94AL85000
- OSTI ID:
- 985497
- Report Number(s):
- SAND2009-4334; TRN: US201016%%2123
- Country of Publication:
- United States
- Language:
- English
Similar Records
Savannah River National Laboratory Participation in the International Atomic Energy Agency CPC Interlaboratory Comparison Exercise 2
Transfer leak studies and comparisons of primary leak standards at the National Bureau of Standards and Sandia National Laboratories
Site environmental report for 2009 : Sandia National Laboratories, California.
Technical Report
·
Fri Oct 28 00:00:00 EDT 2022
·
OSTI ID:985497
Transfer leak studies and comparisons of primary leak standards at the National Bureau of Standards and Sandia National Laboratories
Journal Article
·
Thu May 01 00:00:00 EDT 1986
· J. Vac. Sci. Technol., A; (United States)
·
OSTI ID:985497
+1 more
Site environmental report for 2009 : Sandia National Laboratories, California.
Technical Report
·
Tue Jun 01 00:00:00 EDT 2010
·
OSTI ID:985497