Hermes III endpoint energy calculation from photonuclear activation of 197Au and 58Ni foils

Technical Report ·
DOI:https://doi.org/10.2172/1322293· OSTI ID:1322293
 [1]
  1. Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

A new process has been developed to characterize the endpoint energy of HERMES III on a shot-to-shot basis using standard dosimetry tools from the Sandia Radiation Measurements Laboratory. Photonuclear activation readings from nickel and gold foils are used in conjunction with calcium fluoride thermoluminescent dosimeters to derive estimated electron endpoint energies for a series of HERMES shots. The results are reasonably consistent with the expected endpoint voltages on those shots.