A series of test cases designed to verify the correct implementation of several features of the CPLOAS_2 program are documented. CPLOAS_2 is used to calculate the probability of loss of assured safety (PLOAS) for a weak link (WL)/strong link (SL) system. CPLOAS_2 takes physical properties (e.g., temperature, pressure, etc.) of a WL/SL system and uses these properties and definitions of link failure properties in probabilistic calculations to determine PLOAS. The features being tested include (i) six aleatory distribution forms, (ii) five numerical procedures for the determination of PLOAS (i.e., one quadrature procedure, two simple random sampling procedures, and two importance sampling procedures), and (iii) time and environmental margin calculations. All tests were performed with CPLOAS_2 version 2.10.