Title: Hanford Single-Shell Tank Leak Causes and Locations - 241-BY and 241-TY Farm

Abstract

This document identifies 241-BY Tank Farm (BY Farm) and 241-TY Tank Farm (TY Farm) lead causes and locations for the 100 series leaking tanks (241-BY-103, 241-TY-103, 241-TY-104, 241-TY-105 and 241-TY-106) identified in RPP-RPT-43704, Hanford BY Farm Leak Assessments Report, and in RPP-RPT-42296, Hanford TY Farm Leak Assessments Report. This document satisfies the BY and TY Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.

Authors:
;
Publication Date:
Research Org.:
Hanford Site (HNF), Richland, WA (United States)
Sponsoring Org.:
USDOE Office of Environmental Management (EM)
OSTI Identifier:
1154954
Report Number(s):
RPP-RPT-54911 Rev. 1
M-045-91F; T04; RPP-RPT-42296; RPP-RPT-43704
DOE Contract Number:
DE-AC27-08RV14800
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English

Citation Formats

Girardot, Crystal L., and Harlow, Donald G. Hanford Single-Shell Tank Leak Causes and Locations - 241-BY and 241-TY Farm. United States: N. p., 2014. Web. doi:10.2172/1154954.
Girardot, Crystal L., & Harlow, Donald G. Hanford Single-Shell Tank Leak Causes and Locations - 241-BY and 241-TY Farm. United States. doi:10.2172/1154954.
Girardot, Crystal L., and Harlow, Donald G. Thu . "Hanford Single-Shell Tank Leak Causes and Locations - 241-BY and 241-TY Farm". United States. doi:10.2172/1154954. https://www.osti.gov/servlets/purl/1154954.
@article{osti_1154954,
title = {Hanford Single-Shell Tank Leak Causes and Locations - 241-BY and 241-TY Farm},
author = {Girardot, Crystal L. and Harlow, Donald G.},
abstractNote = {This document identifies 241-BY Tank Farm (BY Farm) and 241-TY Tank Farm (TY Farm) lead causes and locations for the 100 series leaking tanks (241-BY-103, 241-TY-103, 241-TY-104, 241-TY-105 and 241-TY-106) identified in RPP-RPT-43704, Hanford BY Farm Leak Assessments Report, and in RPP-RPT-42296, Hanford TY Farm Leak Assessments Report. This document satisfies the BY and TY Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.},
doi = {10.2172/1154954},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Thu Sep 04 00:00:00 EDT 2014},
month = {Thu Sep 04 00:00:00 EDT 2014}
}

Technical Report:

Save / Share:
  • This document identifies 241-BY Tank Farm (BY Farm) and 241-TY Tank Farm (TY Farm) leak causes and locations for the 100 series leaking tanks (241-BY-103, 241-TY-103, 241-TY-104, 241-TY-105, and 241-TY-106) identified in RPP-RPT-43704, Hanford BY Farm Leak Assessments Report, and in RPP-RPT-42296, Hanford TY Farm Leak Assessments Report. This document satisfies the BY and TY Farm portion of the target (T04) in Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.
  • This document identifies 241-B Tank Farm (B Farm) leak cause and locations for the 100 series leaking tank (241-B-107) identified in RPP-RPT-49089, Hanford B-Farm Leak Inventory Assessments Report. This document satisfies the B Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.
  • This document identifies 241-C Tank Farm (C Farm) leak causes and locations for the 100 series leaking tanks (241-C-101 and 241-C-105) identified in RPP-RPT-33418, Rev. 2, Hanford C-Farm Leak Inventory Assessments Report. This document satisfies the C Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.
  • This document identifies 241-A Tank Farm (A Farm) leak causes and locations for the 100 series leaking tanks (241-A-104 and 241-A-105) identified in RPP-ENV-37956, Hanford A and AX Farm Leak Assessment Report. This document satisfies the A Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.
  • This document identifies 241-U Tank Farm (U Farm) leak causes and locations for the 100 series leaking tanks (241-U-104, 241-U-110, and 241-U-112) identified in RPP-RPT-50097, Rev. 0, Hanford 241-U Farm Leak Inventory Assessment Report. This document satisfies the U-Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.