Hanford Single-Shell Tank Leak Causes and Locations - 241-U Farm

Technical Report ·
DOI:https://doi.org/10.2172/1109483· OSTI ID:1109483
 [1];  [1]
  1. Washington River Protection Solutions, Richland, WA (United States)

This document identifies 241-U Tank Farm (U Farm) leak causes and locations for the 100 series leaking tanks (241-U-104, 241-U-110, and 241-U-112) identified in RPP-RPT-50097, Rev. 0, Hanford 241-U Farm Leak Inventory Assessment Report. This document satisfies the U-Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.