The Spent Nuclear Fuel (SNF) position regarding the Multi-Canister Overpack (MCO) sealing configuration is to initially rely on an American Society of Mechanical Engineers (ASME) Section III Subsection NB code compliant mechanical closure/sealing system to quickly and safely establish and maintain full confinement of radioactive materials prior to and during MCO fuel drying activities. Previous studies have shown the mechanical seal to be the preferred closure method, based on dose, cost, and schedule considerations. The cost and schedule impacts of redesigning the mechanical closure to a welded shield plug do not support changing the closure system. The SNF Project has determined that the combined mechanical/welded closure system meets or exceeds the regulatory requirements to provide redundant seals while accommodating key safety and schedule limitations that are unique to K Basins fuel removal effort.

Research Organization:
HNF Hanford Site (US)
Sponsoring Organization:
US DOE Office of Environmental Management (US)
DOE Contract Number:
AC06-96RL13200
OSTI ID:
11247
Report Number(s):
HNF--3292--REV0; EW7040000; EW7040000
Country of Publication:
United States
Language:
English

Similar Records

Multi Canister Overpack (MCO) Closure Welding Process Parameter Development and Qualification
Journal Article · Mon Sep 15 00:00:00 EDT 2003 · Welding Journal · OSTI ID:816309

Multi-Canister overpack pressure testing
Technical Report · Mon Nov 02 23:00:00 EST 1998 · OSTI ID:11246

Multi-Canister overpack dual pressure rating
Technical Report · Mon Nov 02 23:00:00 EST 1998 · OSTI ID:11245