Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Multi-Canister overpack dual pressure rating

Technical Report ·
DOI:https://doi.org/10.2172/11245· OSTI ID:11245

The SNF Project will change the Multi-Canister Overpack (MCO) design pressure rating in the mechanical closure configuration to 150 psig to permit substitution of 304L/304 stainless steel for the higher cost XM-19 in the MCO collar. The 450 psig pressure rating for the final welded MCO will remain unchanged.

Research Organization:
HNF Hanford Site (US)
Sponsoring Organization:
US DOE Office of Environmental Management (US)
DOE Contract Number:
AC06-96RL13200
OSTI ID:
11245
Report Number(s):
HNF--3267--REV0; EW7040000; EW7040000
Country of Publication:
United States
Language:
English

Similar Records

Multi-Canister overpack pressure testing
Technical Report · Mon Nov 02 23:00:00 EST 1998 · OSTI ID:11246

DESIGN OF THE HANFORD MULTI CANISTER OVERPACK (MCO) & DEVELOPMENT & QUALIFICATION OF THE CLOSURE WELDING PROCESS
Conference · Fri Apr 30 00:00:00 EDT 2004 · OSTI ID:823763

Multi-Canister overpack design pressure rating