Multi-Canister overpack pressure testing
The Multi-Canister Overpack (MCO) shield plug closure assembly will be hydrostatically tested at the fabricator's shop to the 150 psig design test requirement in accordance with the ASME Code. Additionally, the MCO shell and collar will be hydrostatically tested at the fabricator's shop to the 450 psig design test requirement. Commercial practice has not required a pressure test of the closure weld after spent fuel is loaded in the containers. Based on this precedent and Code Case N-595-I, the MCO closure weld will not be pressure tested in the field.