Argon Spill Duct Bellows Leak Test Procedures and Results

Technical Report ·
DOI:https://doi.org/10.2172/1031802· OSTI ID:1031802
This engineering note describes the testing of the argoll spill duct bellows. It includes a detailed explanation of the procedures, along with a summary of the results of the testing done on 2/18/91 and 2/19/91 by Gary Trotter. The original bellows were purchased from Expansion Joint Systems (see Appendix 2). The general conclusion from the testing was that the leaks that were found were small enough so that they would not show up at the design pressure of 0.1 psig. Therefore, the leaks were acceptable, and the conclusion was that the bellows were fit for use.