Effect of stainless steel thimbles on pile reactivity

Technical Report ·
DOI:https://doi.org/10.2172/10188145· OSTI ID:10188145
Failure of a vertical safety rod thimble at 105-B has led to consideration of a stainless steel (SS) thimble as replacement. 1/16 in. SS would result in 4% loss in control power of that safety rod. If all thimbles were replaced by 1/16 in. SS, there would be a reactivity loss of 790 ih.