Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Automated measurement of cavity frequency and cavity tuning at CEBAF

Technical Report ·
DOI:https://doi.org/10.2172/10185891· OSTI ID:10185891
We propose a method here which allows the measurement of the cavity resonance frequency in a frequency range up to {plus_minus}5 kHz from the operating frequency. This is achieved by phase modulation of the incident signal with noise to drive the cavity with a broad band spectrum. The cavity resonance frequency can then be determined from the response signal of the field probe, which has a narrow frequency spectrum due to the high loaded Q of the cavity of 6.6{times}10{sup 6}, corresponding to a cavity bandwidth of 125 Hz.
Research Organization:
Southeastern Universities Research Association, Inc., Newport News, VA (United States). Continuous Electron Beam Accelerator Facility
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC05-84ER40150
OSTI ID:
10185891
Report Number(s):
DOE/ER/40150--230; CEBAF-PR--93-011; ON: DE93040863
Country of Publication:
United States
Language:
English

Similar Records

Superconducting cavity tuner performance at CEBAF
Conference · Tue Jun 01 00:00:00 EDT 1993 · OSTI ID:10172793

Automated frequency tuning of SRF cavities at CEBAF
Technical Report · Sat Dec 30 23:00:00 EST 1995 · OSTI ID:244503

Frequency tuning of the CEBAF upgrade cavities
Conference · Sun Feb 28 23:00:00 EST 1999 · OSTI ID:755239