A neutron dose detector with REM response to 1 GeV

Conference ·
OSTI ID:10184265
; ;  [1];  [2]
  1. Lawrence Berkeley Lab., CA (United States)
  2. Los Alamos National Lab., NM (United States)
The limitation of current remmeters, which do not measure neutron dose equivalents above about 15 MeV, is a serious problem at high-energy accelerator facilities, where a much wider range of neutron energies exist. The purpose of this work was to measure the response of a modified Anderson-Braun (A-B) remmeter to neutron energies up to 1 GeV. The modifications to the standard A-B remmeter were based on the experimental results of Pb(n,xn) reactions.