Monte Carlo calculations of high energy neutron responses for improved Andersson-Braun remmeters
Journal Article
·
· Bulletin of the American Physical Society
OSTI ID:243857
- Los Alamos National Lab., NM (United States)
- Lawrence Berkeley Lab., CA (United States)
By replacing part of the neutron moderator material CH{sub 2} with lead in Andersson-Braun remmeter, the Pb(n,xn) reactions at high neutron energy will increase the sensitivity of the remmeter. Monte Carlo calculations have been carried out for both standard and modified Andersson-Braun remmeters with monoenergetic neutrons (up to 1 GeV), the result of response enhancement agreed with measurements at several high neutron energies. Other possible improvements have also been explored, the results will be discussed.
- OSTI ID:
- 243857
- Report Number(s):
- CONF-9304297--
- Journal Information:
- Bulletin of the American Physical Society, Journal Name: Bulletin of the American Physical Society Journal Issue: 2 Vol. 38; ISSN 0003-0503; ISSN BAPSA6
- Country of Publication:
- United States
- Language:
- English