Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Radiochemistry for the rupture of a Zircaloy-2 clad uranium fuel element in KER-2

Technical Report ·
DOI:https://doi.org/10.2172/10146610· OSTI ID:10146610

During the 1600--2400 shift on August 7, 1960, the delayed neutron monitor on KER Loop 2 indicated a high coolant activity level. Sympathetic responses were also observed on the Loop 1, 3 and 4 monitors. This indicated a possible fuel element failure in Loop 2 and the KE Reactor began shutdown operations immediately. The purpose of this report is to summarize the events pertinent to this reactor outage and to discuss the results obtained from coolant and coupon samples taken from Loop 2 after shutdown.

Research Organization:
General Electric Co., Richland, WA (United States). Hanford Atomic Products Operation
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC06-76RL01830
OSTI ID:
10146610
Report Number(s):
HW--70520; ON: DE94010922
Country of Publication:
United States
Language:
English