Radiochemistry for the rupture of a Zircaloy-2 clad uranium fuel element in KER-1
During the 0800--1600 shift on July 7, 1960, the delayed neutron monitor on KER Loop 1 indicated a high coolant activity level. Sympathetic responses were also recorded on the Loop 3 and Loop 4 instruments indicating a possible fuel element failure in Loop 1. The KE Reactor began shutdown operations immediately thereafter. The purpose of this report is to summarize the events pertinent to this reactor outage and to discuss the results obtained from coolant samples and a thermocouple wire sample taken from Loop 1.
- Research Organization:
- General Electric Co., Richland, WA (United States). Hanford Atomic Products Operation
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC06-76RL01830
- OSTI ID:
- 10145365
- Report Number(s):
- HW--68550; ON: DE94010502
- Country of Publication:
- United States
- Language:
- English
Similar Records
Radiochemistry for the rupture of a Zircaloy-2 clad, natural uranium thermocouple fuel element in KER-1
Radiochemistry for the rupture of a Zircaloy-2 clad uranium fuel element in KER-2
Radiochemistry for the rupture of a Zircaloy-2 clad seven rod cluster fuel element in KER Loop 2
Technical Report
·
Mon Jun 05 00:00:00 EDT 1961
·
OSTI ID:10168312
Radiochemistry for the rupture of a Zircaloy-2 clad uranium fuel element in KER-2
Technical Report
·
Mon May 29 00:00:00 EDT 1961
·
OSTI ID:10146610
Radiochemistry for the rupture of a Zircaloy-2 clad seven rod cluster fuel element in KER Loop 2
Technical Report
·
Thu Jan 21 23:00:00 EST 1960
·
OSTI ID:10171094