skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: An Assessment of the Penetrations in the First Wall Required for Plasma Measurments for Control of an Advanced Tokamak Plasma Demo

Technical Report ·
DOI:https://doi.org/10.2172/973200· OSTI ID:973200

A Demonstration tokamak (Demo) is an essential next step toward a magnetic-fusion based reactor. One based on advanced-tokamak (AT) plasmas is especially appealing because of its relative compactness. However, it will require many plasma measurements to provide the necessary signals to feed to ancillary systems to protect the device and control the plasma. This note addresses the question of how much intrusion into the blanket system will be required to allow the measurements needed to provide the information required for plasma control. All diagnostics will require, at least, the same shielding designs as planned for ITER, while having the capability to maintain their calibration through very long pulses. Much work is required to define better the measurement needs and the quantity and quality of the measurements that will have to be made, and how they can be integrated into the other tokamak structures.

Research Organization:
Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States)
Sponsoring Organization:
USDOE Office of Science (SC)
DOE Contract Number:
DE-ACO2-09CH11466
OSTI ID:
973200
Report Number(s):
PPPL-4498; TRN: US1001907
Country of Publication:
United States
Language:
English