skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Magnet reliability in the Fermilab Main Injector and implications for the ILC

Conference ·
OSTI ID:917080

The International Linear Collider reference design requires over 13000 magnets, of approximately 135 styles, which must operate with very high reliability. The Fermilab Main Injector represents a modern machine with many conventional magnet styles, each of significant quantity, that has now accumulated many hundreds of magnet-years of operation. We review here the performance of the magnets built for this machine, assess their reliability and categorize the failure modes, and discuss implications for reliability of similar magnet styles expected to be used at the ILC.

Research Organization:
Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC02-07CH11359
OSTI ID:
917080
Report Number(s):
FERMILAB-CONF-07-443-TD; TRN: US0804433
Resource Relation:
Conference: Presented at 20th International Conference on Magnet Technology (MT20), Philadelphia, Pennsylvania, 27-31 Aug 2007
Country of Publication:
United States
Language:
English

Similar Records

Space charge measurements with a high intensity bunch at the Fermilab Main Injector
Conference · Tue Mar 01 00:00:00 EST 2011 · OSTI ID:917080

Proposed Fermilab upgrade main injector project. Environmental Assessment
Technical Report · Wed Apr 01 00:00:00 EST 1992 · OSTI ID:917080

Proposed Fermilab upgrade main injector project
Technical Report · Wed Apr 01 00:00:00 EST 1992 · OSTI ID:917080