Title: A Five-Level Cascade Multilever Invertor Three-Phase Motor Drive Using a Single DC Source

Technical Report ·
DOI:https://doi.org/10.2172/901193· OSTI ID:901193

A method is presented showing that a 5-level cascade multilevel inverter for a three-phase permanent magnet synchronous motor drive can be implemented using only a single DC link to supply a standard 3-leg inverter along with three full H-bridges supplied by capacitors. It is shown that the capacitor voltages can be regulated while achieving an output voltage waveform that is 20% greater than that obtained using the standard 3-leg inverter alone. Finally conditions are given in terms of the power factor and modulation index that determine when the capacitor voltage can regulated.