skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Radiation Safety Design for SSRL Storage Ring

Journal Article · · Radiat.Meas.41:172, 2006
OSTI ID:899563

In 2003, the Stanford Synchrotron Radiation Laboratory (SSRL) has upgraded its storage ring to a 3rd generation storage ring (SPEAR3). SPEAR3 is deigned to operate at 500 mA stored beam current and 3 GeV energy. The 234-meter circumference SPEAR3 ring utilizes 60-cm-thick concrete lateral walls, 30-cm-thick concrete roof, as well as 60-cm or 90-cm-thick concrete ratchet walls. A total of 3.5 x 10{sup 15} e{sup -}/y will be injected into the ring with an injection power of 4 W and an injection efficiency of 75%. Normal beam losses occur due to both injection and stored beam operations in the total of 20 low loss as well as 3 high loss limiting apertures. During the 6-minutes injection period, an instantaneous power loss of 0.05 W occurs at each low loss aperture. When averaged over the operational year, the loss of both the injection and stored beams is equivalent to an average loss of 2 mW at each low loss aperture. On the other hand, the average losses in the high loss apertures are 16 mW for the injection septum, 47 mW for the beam abort dump, and 13 mW for the ring stoppers. The shielding requirements for losses in the new ring were based on a generic approach that used both FLUKA Monte Carlo particle generation and transport code and empirical computer codes and formulae.

Research Organization:
SLAC National Accelerator Lab., Menlo Park, CA (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC02-76SF00515
OSTI ID:
899563
Report Number(s):
SLAC-PUB-12308; TRN: US0701977
Journal Information:
Radiat.Meas.41:172, 2006, Journal Name: Radiat.Meas.41:172, 2006
Country of Publication:
United States
Language:
English