Alternatives generation and analysis for double-shell tank primary ventilation systems emissions control and monitoring
This AGA addresses the question: ''What equipment upgrades, operational changes, and/or other actions are required relative to the DST tanks farms' ventilation systems to support retrieval, staging (including feed sampling), and delivery of tank waste to the Phase I private contractor?'' Issues and options for the various components within the ventilation subsystem affect each other. Recommended design requirements are presented and the preferred alternatives are detailed.
- Research Organization:
- ARES (US)
- Sponsoring Organization:
- ENVIRONMENTAL MANAGEMENT (US)
- DOE Contract Number:
- AC06-96RL13200
- OSTI ID:
- 798017
- Report Number(s):
- HNF-4245, Rev.0; TRN: US0205994
- Resource Relation:
- Other Information: PBD: 30 Sep 1999
- Country of Publication:
- United States
- Language:
- English