skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: ADVANCED HYBRID PARTICULATE COLLECTOR

Technical Report ·
DOI:https://doi.org/10.2172/794324· OSTI ID:794324

A new concept in particulate control, called an advanced hybrid particulate collector (AHPC), is being developed under funding from the U.S. Department of Energy. The AHPC combines the best features of electrostatic precipitators (ESPs) and baghouses in an entirely novel manner. The AHPC concept combines fabric filtration and electrostatic precipitation in the same housing, providing major synergism between the two methods, both in the particulate collection step and in transfer of dust to the hopper. The AHPC provides ultrahigh collection efficiency, overcoming the problem of excessive fine-particle emissions with conventional ESPs, and solves the problem of reentrainment and re-collection of dust in conventional baghouses. Phase I of the development effort consisted of design, construction, and testing of a 5.7-m{sup 3}/min (200-acfm) working AHPC model. Results from both 8-hr parametric tests and 100-hr proof-of-concept tests with two different coals demonstrated excellent operability and greater than 99.99% fine-particle collection efficiency. Since all of the developmental goals of Phase I were met, the approach was scaled up in Phase II to a size of 255 m{sup 3}/min (9000 acfm) (equivalent in size to 2.5 MW) and was installed on a slipstream at the Big Stone Power Plant. For Phase II, the AHPC at Big Stone Power Plant was operated continuously from late July 1999 until mid-December 1999. The Phase II results were highly successful in that ultrahigh particle collection efficiency was achieved, pressure drop was well controlled, and system operability was excellent. For Phase III, the AHPC was modified into a more compact configuration, and components were installed that were closer to what would be used in a full-scale commercial design. The modified AHPC was operated from April to July 2000. While operational results were acceptable during this time, inspection of bags in the summer of 2000 revealed some membrane damage to the fabric that appeared to be caused by electrical effects. Subsequently, extensive theoretical, bench-scale, and pilot-scale investigations were completed to find an approach to prevent bag damage without compromising AHPC performance. Results showed that the best bag protection and AHPC performance were achieved by using a perforated plate installed between the discharge electrodes and bags. This perforated-plate design was then installed in the 2.5-MW AHPC at Big Stone Power Plant in Big Stone City, South Dakota, and the AHPC was operated from March to June 2001. Results showed that the perforated-plate design solved the bag damage problem and offered even better AHPC performance than the previous design. All of the AHPC performance goals were met, including ultrahigh collection efficiency, high air-to-cloth ratio, reasonable pressure drop, and long bag-cleaning interval.

Research Organization:
National Energy Technology Laboratory (NETL), Pittsburgh, PA, Morgantown, WV, and Albany, OR (United States)
Sponsoring Organization:
US Department of Energy (US)
DOE Contract Number:
FC26-99FT40719
OSTI ID:
794324
Report Number(s):
FC26-99FT40719-07; TRN: US200210%%10
Resource Relation:
Other Information: PBD: 1 Dec 2001
Country of Publication:
United States
Language:
English