Title: Coherent Synchrotron Radiation in Multiply-Connected Vacuum Chamber

Technical Report ·
DOI:https://doi.org/10.2172/763757· OSTI ID:763757

Coherent synchrotron radiation (CSR) in a singly-connected vacuum chamber is, as it is well known, strongly suppressed for harmonics n{sub cr} less-than-or-equal to (R/h){sup 3/2}, where R is the radius of curvature and h is characteristic transverse dimension. If, however, the vacuum chamber has a multiply-connected topology, the critical frequency is zero and this restriction is not valid anymore. Estimation for radiated power in a multiply-connected chamber is presented here including CSR in electrostatic separator and at the LHC collider.

Research Organization:
SLAC National Accelerator Lab., Menlo Park, CA (United States)
Sponsoring Organization:
USDOE Office of Energy Research (ER) (US)
DOE Contract Number:
AC03-76SF00515
OSTI ID:
763757
Report Number(s):
SLAC-PUB-8428; TRN: US0004796
Resource Relation:
Other Information: PBD: 25 Apr 2000
Country of Publication:
United States
Language:
English

Similar Records

Efficient computation of coherent synchrotron radiation in a rectangular chamber
Journal Article · Tue Sep 27 00:00:00 EDT 2016 · Physical Review Accelerators and Beams · OSTI ID:763757

Coherent synchrotron radiation and bunch stability in a compactstorage ring
Journal Article · Fri Apr 09 00:00:00 EDT 2004 · Physical Review E Special Topics - Accelerators and Beams · OSTI ID:763757

Coherent Synchrotron Radiation and Bunch Stability in a Compact Storage Ring