Title: Certification of packagings: compliance with DOT specification 7A packaging requirements

Technical Report ·
DOI:https://doi.org/10.2172/7251525· OSTI ID:7251525

A study was conducted to determine which of the packagings currently listed in CFR 49 Section 173.395 a.1-5, meet the Specification 7A requirements (CFR 49 Section 173.350). According to DOT HM-111 the present listing of various authorized DOT specifications in Section 173.394 and Section 173.395 (Type A containers) of ICC Tariff No. 27 would be deleted with complete reliance being placed on the use of DOT 7A, Type A general packaging specification. Each user of a Specification 7A package would be required to document and maintain on file for one year a written record of his determination of compliance with the DOT Specification 7A performance requirements. All the specification packagings listed in CFR 49 Section 173.395a.1-5 were tested and shown to meet the Specification 7A criteria; however, in many cases qualifications were placed on their use. Forty-nine specification packagings were tested and shown to meet the DOT Specification 7A performance requirements and since there were several styles of some specific packagings, this amounts to greater than 80 packagings. The extensive testing generally indicated a high degree of containment integrity in the packagings tested and the documentation discussed is a valuable tool for shippers of Type A quantities of radioactive materials. (DLC)

Research Organization:
Mound Plant (MOUND), Miamisburg, OH (United States)
DOE Contract Number:
EY-76-C-04-0053
OSTI ID:
7251525
Report Number(s):
MLM-2324; TRN: 77-000341
Country of Publication:
United States
Language:
English