skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Review and evaluation of TDI diesel generator owner's group program plan

Technical Report ·
DOI:https://doi.org/10.2172/6855917· OSTI ID:6855917

This report documents a review, performed by the Pacific Northwest Laboratory (PNL), of the Transamerica Delaval, Inc. (TDI) Diesel Generator Owner's Group Program Plan. This report was prepared as part of the technical support PNL is providing to the US Nuclear Regulatory Commission (NRC), Division of Licensing, on matters pertaining to the reliability of TDI diesel generators as emergency power sources for safety-related nuclear systems. The report presents the comments and conclusions reached by PNL, with the advice and counsel of five diesel engine consultants, on the principal elements of the Owners' Group Plan: Generic Problem Resolution, Design Review/Quality Revalidation, and Engine Testing and Inspection. Also included are PNL's comments on the related issues of Surveillance and Maintenance, and Administrative Controls. The conclusions drawn from PNL's evaluation of these issues form the basis for two additional topics addressed in the report: Critical Elements Required to Establish Diesel Engine Operability and Reliability, and Considerations for Interim Licensing.

Research Organization:
Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
DOE Contract Number:
AC06-76RL01830
OSTI ID:
6855917
Report Number(s):
PNL-5161; ON: DE84013986
Country of Publication:
United States
Language:
English