Title: High gain micro-channel plate multipliers for particle tracking or single photo-electron counting

Conference ·
OSTI ID:6720805

Micro-channel plate multipliers have been used to detect the passage of relativistic charged particles. Measurements of the detection efficiency and pulse height response versus micro-channel plate gain are presented for one, two and three micro-channel plate arrays. Values describing temporal response and transit time jitter are also given. In a separate measurement, the response of a single micro-channel plate to individual slow electrons (less than or equal to 1 keV) was studied. By using a special technique output bunches as small as three electrons may be seen for low average micro-channel plate gain. The results of attempts to improve the micro-channel plate response are also presented.

Research Organization:
Brookhaven National Lab., Upton, NY (USA)
DOE Contract Number:
AC02-76CH00016
OSTI ID:
6720805
Report Number(s):
BNL-28610; CONF-801103-31; TRN: 81-001981
Resource Relation:
Conference: IEEE nuclear science symposium, Orlando, FL, USA, 5 Nov 1980
Country of Publication:
United States