Timing resolution of Shisk-Kebab'' lead scintillator sandwich calorimeters
- Brookhaven National Lab., Upton, NY (United States)
- Institut Fiziki Vysokikh Ehnergij, Protvino (Russian Federation)
We have constructed lead scintillator sandwich calorimeters with 1/4 [chi][sub o] sampling frequency and total thickness [approximately]16[chi][sub o]. The 4 mm thick scintillator plates are read out by wavelength shifter fibers 1 mm in diameter which pass through holes penetrating the plates on a .95 cm [times] .95 cm grid (Shish-Kebab geometry). We tested these modules in the A2 test beam at Brookhaven using low energy electrons and hadrons. Results are here presented on electron energy and time-of-flight resolution obtained with various combinations of scintillators and wavelength shifters. We also describe results on e/[pi] separation obtained with a new technique for the longitudinal segmentation.
- Research Organization:
- Brookhaven National Lab., Upton, NY (United States)
- Sponsoring Organization:
- USDOE; USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC02-76CH00016
- OSTI ID:
- 6668574
- Report Number(s):
- BNL-48457; CONF-9209263-12; ON: DE93009332
- Resource Relation:
- Conference: 3. international conference on calorimetry in high energy physics, Corpus Christi, TX (United States), 29 Sep - 2 Oct 1992
- Country of Publication:
- United States
- Language:
- English
Similar Records
Testing of the scintillation sandwich prototype
ALICE electromagnetic calorimeter prototype test
Related Subjects
SHOWER COUNTERS
TIME RESOLUTION
LEAD
SOLID SCINTILLATION DETECTORS
TIME-OF-FLIGHT METHOD
ELEMENTS
MEASURING INSTRUMENTS
METALS
RADIATION DETECTORS
RESOLUTION
SCINTILLATION COUNTERS
TIMING PROPERTIES
440104* - Radiation Instrumentation- High Energy Physics Instrumentation