skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Heat transfer through He II in a 9. 6 m long 35 mm ID tube

Conference ·
OSTI ID:6546459

The limiting heat flux at the onset of He I was measured in a 9.6 m long tube of 35 mm ID at a bath temperature between 1.8 K and T/sub lambda/ and a pressure of 1 atm. The measured limiting heat flux during axial heating is 50% more than end heating at the same bath temperature. Both cases agrees with the Gorter-Mellink mutual friction theory.

Research Organization:
Lawrence Berkeley Lab., CA (USA)
DOE Contract Number:
AC03-76SF00098
OSTI ID:
6546459
Report Number(s):
LBL-18134; CONF-840705-3; ON: DE84016949
Resource Relation:
Conference: 10. international conference on cryogenic engineering, Espoo, Finland, 31 Jul 1984; Other Information: Portions are illegible in microfiche products
Country of Publication:
United States
Language:
English