Title: A 250-GHz CARM (Cyclotron Auto Resonance Maser) oscillator experiment driven by an induction linac

Conference ·
OSTI ID:6542692
; ;  [1]; ;  [2]
  1. Lawrence Livermore National Lab., CA (USA)
  2. California Univ., Los Angeles, CA (USA)

A 250-GHz Cyclotron Auto Resonance Maser (CARM) oscillator has been designed and constructed and will be tested using a 1-kA, 2-MeV electron beam produced by the induction linac at the Accelerator Research Center (ARC) facility of Lawrence Livermore National Laboratory (LLNL). The oscillator circuit was made to operate in the TE{sub 11} mode at ten times cutoff using waveguide Bragg reflectors to create an external cavity Q of 8000. Theory predicts cavity fill times of less than 30 ns (pulse length) and efficiencies approaching 20% is sufficiently low transverse electron velocity spreads are maintained (2%).

Research Organization:
Lawrence Livermore National Lab., CA (USA)
Sponsoring Organization:
DOE/DP
DOE Contract Number:
W-7405-ENG-48
OSTI ID:
6542692
Report Number(s):
UCRL-JC-104102; CONF-9009166-6; ON: DE91000790; TRN: 90-033929
Resource Relation:
Conference: 12. international free electron laser conference (FEL-12), Paris (France), 17-21 Sep 1990
Country of Publication:
United States
Language:
English