In-reactor, safety experiments performed in the Sodium Loop Safety Facility (SLSF) rely on comprehensive posttest examinations (PTE) to characterize the postirradiation condition of the cladding, fuel, and other test-subassembly components. PTE information and on-line instrumentation data, are analyzed to identify the sequence of events and the severity of the accident for each experiment. Following in-reactor experimentation, the SLSF loop and test assembly are transported to the Hot Fuel Examination Facility (HFEF) for initial disassembly. Goals of the HFEF-phase of the PTE are to retrieve the fuel bundle by dismantling the loop and withdrawing the test assembly, to assess the macro-condition of the fuel bundle by nondestructive examination techniques, and to prepare the fuel bundle for shipment to the Alpha-Gamma Hot Cell Facility (AGHCF) at Argonne National Laboratory.

Research Organization:
Argonne National Lab., IL (USA)
DOE Contract Number:
W-31-109-ENG-38
OSTI ID:
6460458
Report Number(s):
CONF-820406-32; ON: DE83009083
Resource Relation:
Conference: ANS topical meeting on fast, thermal and fusion reactor experiments, Salt Lake City, UT, USA, 12 Apr 1982
Country of Publication:
United States
Language:
English