skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: ROC (Receiver Operating Characteristics) study of maximum likelihood estimator human brain image reconstructions in PET (Positron Emission Tomography) clinical practice

Conference ·
OSTI ID:6071027
; ;  [1]; ; ; ; ;  [2]
  1. Lawrence Berkeley Lab., CA (USA)
  2. California Univ., Los Angeles, CA (USA)

This paper will report on the progress to date in carrying out Receiver Operating Characteristics (ROC) studies comparing Maximum Likelihood Estimator (MLE) and Filtered Backprojection (FBP) reconstructions of normal and abnormal human brain PET data in a clinical setting. A previous statistical study of reconstructions of the Hoffman brain phantom with real data indicated that the pixel-to-pixel standard deviation in feasible MLE images is approximately proportional to the square root of the number of counts in a region, as opposed to a standard deviation which is high and largely independent of the number of counts in FBP. A preliminary ROC study carried out with 10 non-medical observers performing a relatively simple detectability task indicates that, for the majority of observers, lower standard deviation translates itself into a statistically significant detectability advantage in MLE reconstructions. The initial results of ongoing tests with four experienced neurologists/nuclear medicine physicians are presented. Normal cases of {sup 18}F -- fluorodeoxyglucose (FDG) cerebral metabolism studies and abnormal cases in which a variety of lesions have been introduced into normal data sets have been evaluated. We report on the results of reading the reconstructions of 90 data sets, each corresponding to a single brain slice. It has become apparent that the design of the study based on reading single brain slices is too insensitive and we propose a variation based on reading three consecutive slices at a time, rating only the center slice. 9 refs., 2 figs., 1 tab.

Research Organization:
Lawrence Berkeley Lab., CA (USA)
Sponsoring Organization:
DOE/ER
DOE Contract Number:
AC03-76SF00098
OSTI ID:
6071027
Report Number(s):
LBL-29711; CONF-9010220-17; ON: DE91005371; TRN: 91-004206
Resource Relation:
Conference: 1990 IEEE nuclear science symposium, Arlington, VA (USA), 23-27 Oct 1990
Country of Publication:
United States
Language:
English

Similar Records

Statistical analysis of maximum likelihood estimator images of human brain FDG PET studies
Journal Article · Tue Jun 01 00:00:00 EDT 1993 · IEEE Transactions on Medical Imaging (Institute of Electrical and Electronics Engineers); (United States) · OSTI ID:6071027

Precision and accuracy of regional radioactivity quantitation using the maximum likelihood EM reconstruction algorithm
Journal Article · Thu Sep 01 00:00:00 EDT 1994 · IEEE Transactions on Medical Imaging (Institute of Electrical and Electronics Engineers); (United States) · OSTI ID:6071027

A maximum likelihood method for calculation of tomographic region-of-interest (ROI) values
Conference · Wed May 01 00:00:00 EDT 1985 · J. Nucl. Med.; (United States) · OSTI ID:6071027