skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Coarse-coal hydrotransport studies using the separate effects test stand: FY 1980-1981

Technical Report ·
DOI:https://doi.org/10.2172/6000607· OSTI ID:6000607

The Separate Effects Test Stand (SETS) was built to evaluate the rotating pipe-wheel stand concept for hydrotransport testing and to obtain hydrotransport data in support of the US Department of Energy's Hydraulic Transport Research Facility (HTRF). The SETS program involved three phases of testing. The first phase was to evaluate the wheel test stand as an adequate mechanism for testing the hydrotransport of coarse-particle coal through pipe. The second phase was to obtain preliminary data on coal head loss (flow pressure drop) during hydrotransport. The third phase was to determine the effects of coal hydrotransport on water quality. Other data obtained during the program included pipe wear and the size degradation of coal particles. The SETS was tested with water only and the resultant head loss data were compared with head loss values recorded for water flow in staight pipe. These tests were run to determine how well the SETS modeled straight pipe flow.

Research Organization:
Battelle Pacific Northwest Labs., Richland, WA (United States)
DOE Contract Number:
AC06-76RL01830
OSTI ID:
6000607
Report Number(s):
PNL-4011; ON: DE82001045
Country of Publication:
United States
Language:
English