Title: A comparison of L-band and C-band rf guns as sources for inline-injection systems

Technical Report ·
DOI:https://doi.org/10.2172/31688· OSTI ID:31688
;  [1];  [2]
  1. Brookhaven National Lab., Upton, NY (United States)
  2. Forschungszentrum Rossendorf, Dresden (Germany)

We consider the beam dynamics associated with installing a BNL type 1 1/2 cell L-band or C-band rf gun before two TESLA L-band cryomodules. This system will deliver a 25 MeV electron beam with peak currents on the order of 100 A suitable for further magnetic compression. evaluate the injection systems utilizing the electron beam dynamic code PARMELA from the point of view of minimizing the transverse invariant emittance.

Research Organization:
Brookhaven National Lab. (BNL), Upton, NY (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC02-76CH00016
OSTI ID:
31688
Report Number(s):
BNL-52448; CAP-108-94R; ON: DE95006770; TRN: 95:008867
Resource Relation:
Other Information: PBD: Dec 1994
Country of Publication:
United States
Language:
English