skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Enhanced Component Performance Study: Motor Driven Pumps 1998–2022

Technical Report ·
DOI:https://doi.org/10.2172/2301600· OSTI ID:2301600

This report presents an enhanced performance evaluation of motor-driven pumps (MDPs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2022 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The MDP failure modes considered for standby systems are fail to start (FTS), fail to run (FTR) for one hour of operation (FTR=1H), FTR after one hour of operation (FTR>1H), and for normally running systems FTS and FTR. An eight-hour unreliability estimate is also calculated and trended. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. The following increasing trends were identified for MDPs for the most recent 10-year period: (1) Standby MDP frequency of start demands (demands per reactor year), (2) Standby MDP frequency of FTR=1H hours (hours per reactor year), (3) Standby MDP frequency of FTR>1H hours, and (4) Normally running MDP frequency of run hours. The following decreasing trends were identified for MDPs for the most recent 10-year period: (1) Standby MDP FTR=1H failure probability, (2) Normally running MDP FTR failure rate, (3) Standby MDP unavailability, (4) Standby MDP total unreliability (8-hour mission), and (5) Normally running MDP total unreliability (8-hour mission).

Research Organization:
Idaho National Laboratory (INL), Idaho Falls, ID (United States)
Sponsoring Organization:
USDOE; USNRC
DOE Contract Number:
AC07-05ID14517; 31310019N0006
OSTI ID:
2301600
Report Number(s):
INL/RPT-23-73955-Rev000
Country of Publication:
United States
Language:
English

Similar Records

Enhanced Component Performance Study: Motor-Driven Pumps 1998-2020
Technical Report · Tue Mar 01 00:00:00 EST 2022 · OSTI ID:2301600

Enhanced Component Performance Study: Turbine Driven Pumps 1998–2022
Technical Report · Sat Jul 01 00:00:00 EDT 2023 · OSTI ID:2301600

Enhanced Component Performance Study: Turbine-Driven Pumps 1998-2020
Technical Report · Tue Mar 01 00:00:00 EST 2022 · OSTI ID:2301600