skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: A Field Study of Nonintrusive Load Monitoring Devices and Implications for Load Disaggregation

Journal Article · · Sensors
DOI:https://doi.org/10.3390/s23198253· OSTI ID:2192971

Evaluations of nonintrusive load monitoring (NILM) algorithms and technologies have mostly occurred in constrained, artificial environments. However, few field evaluations of NILM products have taken place in actual buildings under normal operating conditions. This paper describes a field evaluation of a state-of-the-art NILM product, tested in eight homes. The match rate metric—a technique recommended by a technical advisory group—was used to measure the NILM’s success in identifying specific loads and the accuracy of the energy consumption estimates. A performance assessment protocol was also developed to address common issues with NILM mislabeling and ground-truth comparisons that have not been sufficiently addressed in past evaluations. The NILM product’s estimates were compared to the submetered consumption of eight major appliances. Overall, the product had good performance in disaggregating the energy consumption of the electric water heaters, which included both electric resistance and heat-pump water heaters, but only a fair accuracy with refrigerators, dryers, and air conditioners. The performance was poor for cooking equipment, furnace fans, clothes washers, and dishwashers. Moreover, the product was often unable to detect major loads in homes. Typically, two or more appliances were not detected in a home. At least two dryers, furnace fans, and air conditioners went undetected across the eight homes. On the other hand, the dishwasher was detected in all homes where available or monitored. The key findings were qualitatively compared to those of past field evaluations. Potential areas for improvement in NILM product performance were determined along with areas where complementary technologies may be able to aid in load-disaggregation applications.

Research Organization:
Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States)
Sponsoring Organization:
USDOE Office of Energy Efficiency and Renewable Energy (EERE), Energy Efficiency Office. Building Technologies Office
Grant/Contract Number:
AC05-76RL01830; AC02-05CH11231
OSTI ID:
2192971
Report Number(s):
PNNL-SA-182568
Journal Information:
Sensors, Vol. 23, Issue 19; ISSN 1424-8220
Publisher:
MDPI AGCopyright Statement
Country of Publication:
United States
Language:
English

References (7)

Dataport and NILMTK: A building data set designed for non-intrusive load monitoring conference December 2015
How does Load Disaggregation Performance Depend on Data Characteristics? conference June 2020
Non-intrusive electrical load monitoring in commercial buildings based on steady-state and transient load-detection algorithms journal January 1996
Deep Learning-Based Non-Intrusive Commercial Load Monitoring journal July 2022
Practical limits to the use of non-intrusive load monitoring in commercial buildings journal November 2021
Performance evaluation in non‐intrusive load monitoring: Datasets, metrics, and tools—A review journal May 2018
NILM based Energy Disaggregation Algorithm for Dairy Farms
  • Yadav, Akhilesh; Sinha, Anuj; Saidi, Abdessamad
  • BuildSys '20: The 7th ACM International Conference on Systems for Energy-Efficient Buildings, Cities, and Transportation, Proceedings of the 5th International Workshop on Non-Intrusive Load Monitoring https://doi.org/10.1145/3427771.3427846
conference November 2020