Alpha contamination assessment for D&D activities: Monitoring inside glove boxes and vessels
We have developed a new approach to glove box monitoring that involves drawing air out of one glove port through a detection grid that collects ions created in the air inside the glove box by ionizing radiation, especially alpha radiation. The charge deposited on the detection grid by the ions is measured with a sensitive electrometer. The air can be circulated back to the glove box through the other glove port, preventing contamination from leaving the glove box and detector system. Initial experiments using a mock-up constructed of sheet metal indicate that this technology provides the measurement technique needed to perform a defensible, non-invasive measurement of alpha contamination inside glove boxes destined for waste disposal. This can result in an enormous cost savings if a given glove box can be shown to fall into the catagory of Low-Level Waste rather than Trans-Uranic Waste. Considering that hundreds of glove boxes contaminated with plutonium will be taken out of service at various nuclear facilities over the next few years, the potential cost savings associated with disposal as LLW rather than TRU waste are substantial.
- Research Organization:
- Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- W-7405-ENG-36
- OSTI ID:
- 204714
- Report Number(s):
- LA-13060-MS; ON: DE96007456; TRN: 96:008735
- Resource Relation:
- Other Information: PBD: Feb 1996
- Country of Publication:
- United States
- Language:
- English
Similar Records
Retrofit of an Engineered Glove-port to a Los Alamos National Laboratory's Plutonium Facility Glovebox
Strategy for decommissioning of the glove-boxes in the Belgonucleaire Dessel MOX fuel fabrication plant