skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Debuncher 4-8 GHZ Pickup Tests II

Technical Report ·
DOI:https://doi.org/10.2172/1967389· OSTI ID:1967389
 [1]
  1. Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States)

This document describes the second set of tests that were performed on prototype stochastic cooling pickups located in the 30 sector of the Debuncher. The pickups consisted of a slow wave slot pickup with a center frequency of 6 GHz, an array of sixteen 100 Ω 2-4 GHz planar loop pickups, and an array of eight 100 Ω 2-4 GHz stripline pickups of the TEV I design. The purpose of these tests was to measure the sensitivity of these different types of pickups under the exact same beam conditions.

Research Organization:
Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States)
Sponsoring Organization:
USDOE Office of Science (SC), High Energy Physics (HEP)
DOE Contract Number:
AC02-07CH11359
OSTI ID:
1967389
Report Number(s):
FERMILAB-PBAR-NOTE-565; oai:inspirehep.net:862789; TRN: US2403216
Country of Publication:
United States
Language:
English

Similar Records

Debuncher 4-8 GHz Pickup Tests
Technical Report · Mon Apr 14 00:00:00 EDT 1997 · OSTI ID:1967389

Slotted Waveguide Slow-Wave Stochastic Cooling Arrays
Technical Report · Fri Jan 01 00:00:00 EST 1999 · OSTI ID:1967389

Evaluation of te 4-8 GHZ Debuncher Upgrade Prototype Stochastic Cooling Pickup and Kicker Tanks
Technical Report · Sat May 09 00:00:00 EDT 1998 · OSTI ID:1967389

Related Subjects