Title: Eddy current studies for the beam screen of the Electron-Ion Collider hadron storage ring superconducting magnets

Technical Report ·
DOI:https://doi.org/10.2172/1893746· OSTI ID:1893746
 [1];  [1]
  1. Brookhaven National Lab. (BNL), Upton, NY (United States)

A copper-clad stainless steel beam screen will be installed in each of the Relativistic Heavy Ion Collider (RHIC) superconducting (SC) magnets used for making the Electron-Ion Collider (EIC) Hadron Storage Ring (HSR). Eddy currents are induced within conductors to oppose a changing magnetic flux. Eddy currents will appear on the EIC HSR beam screens during ramp up and ramp down, after a magnet quenches and when reversing the polarity of the γ transition jump quadrupoles during γ transition crossing. This study evaluates the magnitude of the eddy currents, the temperature increase due to Joule heating and the stress at the beam screens from the eddy-current induced force.