Journal Article · · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
 [1];  [1];  [1];  [1];  [2];  [1];  [1];  [3];  [4];  [1];  [1]
  1. Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
  2. Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Brookhaven National Lab. (BNL), Upton, NY (United States)
  3. Wayne State Univ., Detroit, MI (United States)
  4. Academia Sinica, Taipei (Taiwan)

Between Run II commissioning in early 2001 and the end of operations in September 2011, the Tevatron collider delivered 12~fb$$^{-1}$$ of $$p\bar{p}$$ collisions at $$\sqrt{s}=1.96$$ TeV to the Collider Detector at Fermilab (CDF). During that time, the CDF silicon vertex detector was subject to radiation doses of up to 12 Mrad. After the end of operations, the silicon detector was annealed for 24 days at $$18^{\circ}$$C. In this paper, we present a measurement of the change in the bias currents for a subset of sensors during the annealing period. We also introduce a novel method for monitoring the depletion voltage throughout the annealing period. The observed bias current evolution can be characterized by a falling exponential term with time constant $$\tau_I=17.88\pm0.36$$(stat.)$$\pm0.25$$(syst.) days. We observe an average decrease of $$(27\pm3)\%$$ in the depletion voltage, whose evolution can similarly be described by an exponential time constant of $$\tau_V=6.21\pm0.21$$ days. These results are consistent with the Hamburg model within the measurement uncertainties.

Research Organization:
Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Brookhaven National Lab. (BNL), Upton, NY (United States)
Sponsoring Organization:
USDOE Office of Science (SC), High Energy Physics (HEP)
Grant/Contract Number:
AC02-07CH11359
OSTI ID:
1854762
Report Number(s):
FERMILAB-PUB-13-576-E-PPD; arXiv:1312.6021; oai:inspirehep.net:1273489; TRN: US2304957
Journal Information:
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 743; ISSN 0168-9002
Publisher:
ElsevierCopyright Statement
Country of Publication:
United States
Language:
English

References (3)

A measurement of the radiation environment in the CDF tracking volume
  • Tesarek, R. J.; D'Auria, S.; Hocker, A.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 514, Issue 1-3 https://doi.org/10.1016/j.nima.2003.08.104
journal November 2003
Operational experience, improvements, and performance of the CDF Run II silicon vertex detector
  • Aaltonen, T.; Behari, S.; Boveia, A.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 729 https://doi.org/10.1016/j.nima.2013.07.015
journal November 2013
Temperature dependence of the current generated in Si bulk journal October 2013