Pulsed Operation of CEBAF for JLEIC Injection
Conference
·
OSTI ID:1647163
- Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)
JLab Electron Ion Collider (JLEIC) is planning to use the recently upgraded 12 GeV CEBAF 1497 MHz SRF CW recirculating linac as a full-energy injector for the electron collider ring. The JLEIC electron injection requires 3-4µs long bunch trains with a 20-400ms spacing in between, resulting in uneven beam loading for the CW CEBAF. With the high beam current in JLEIC collider rings, the low duty factor of injection also requires to a very high pulsed beam current from CEBAF, exacerbating the transient beam loading issue. In this paper, we will present CEBAFs detailed pulsed operation scheme for JLEIC injection, as well as some experimental results at CEBAF.
- Research Organization:
- Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)
- Sponsoring Organization:
- USDOE Office of Science (SC), Nuclear Physics (NP)
- DOE Contract Number:
- AC05-06OR23177
- OSTI ID:
- 1647163
- Report Number(s):
- JLAB-ACP-18-2899; DOE/OR/23177-5024
- Resource Relation:
- Conference: Linac 2018, Beijing, China, 16–21 September 2018
- Country of Publication:
- United States
- Language:
- English
Similar Records
Conceptual MEIC electron ring injection scheme using CEBAF as a full energy injector
TRANSIENT BEAM LOADING EFFECTS IN RF SYSTEMS IN JLEIC
JLab CW Cryomodules for 4th Generation Light Sources
Conference
·
Tue Sep 01 00:00:00 EDT 2015
·
OSTI ID:1647163
+3 more
TRANSIENT BEAM LOADING EFFECTS IN RF SYSTEMS IN JLEIC
Conference
·
Sun May 01 00:00:00 EDT 2016
·
OSTI ID:1647163
+1 more
JLab CW Cryomodules for 4th Generation Light Sources
Conference
·
Wed Jan 23 00:00:00 EST 2008
·
OSTI ID:1647163
+16 more