Title: Radiation shielding analysis of the concrete hutch of a long beamline of the Advanced Photon Source Upgrade project

Journal Article · · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
 [1]
  1. Argonne National Lab. (ANL), Argonne, IL (United States)

The radiation shielding analysis of the external concrete enclosure of a feature long beamline of the Advanced Photon Source Upgrade project is described in this work. The beamline has 2 undulators that can operate in two different configurations and the source terms are estimated for the worst configuration using the SRW code in the OASYS package as well as the STAC8 code. The shielding analysis is carried out using the STAC8 code, and for the case of pink beam, with the FLUKA code also. Effective dose rates on contact with the outside surface of the concrete walls for pink, reflected full spectrum and monochromatic beams are calculated. For the monochromatic beams, 2 sets of discrete bandwidths (BW) from the Double Crystal Monochromator (DCM) and the full reflectance of the Double Multilayer Monochromator (DMM) are used. Further, due to the size of the direct beam and the energy domain of interest in the direct and scattered fields, the importance of the equivalent dose to the lens of the eye is discussed with respect to the shielding calculations of such facilities. The dose rates outside the concrete hutch in the lateral directions calculated using STAC8 is about 50% higher than the FLUKA results for the case of pink beam but may be considered as a reasonable agreement due to the differences in the calculational methodologies. Those dose rates in the lateral and forward directions are higher for the pink beam to allow full occupancy from the radiation protection point of view. For the full spectrum after 3 reflections, the effective dose rates are less than 0.5 Sv/h in the lateral direction but is higher in the forward region below about 22° with respect to the beam direction. For the DCM beams, except for the scenario with one mirror and 0.1%BW, all dose rates are less than 0.5 Sv/h outside the concrete hutch in the lateral directions. Here, the higher harmonics are what contributes to the dose outside the shield and the bandwidths assumed to derive the photon flux thus becomes important. The dose rates with the DMM are generally lower compared to the 0.1% BW DCM beam but are higher than the results obtained with XOP calculated bandwidths.

Research Organization:
Argonne National Laboratory (ANL), Argonne, IL (United States)
Sponsoring Organization:
USDOE Office of Science (SC), Basic Energy Sciences (BES)
Grant/Contract Number:
AC02-06CH11357
OSTI ID:
1615745
Alternate ID(s):
OSTI ID: 1692143
Journal Information:
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 968, Issue C; ISSN 0168-9002
Publisher:
ElsevierCopyright Statement
Country of Publication:
United States
Language:
English
Citation Metrics:
Cited by: 2 works
Citation information provided by
Web of Science

References (13)

XOP v2.4: recent developments of the x-ray optics software toolkit conference September 2011
Monitoring the eye lens: how do the international organisations react? journal September 2014
The FLUKA Code: Developments and Challenges for High Energy and Medical Applications journal June 2014
Dose conversion coefficients for photon exposure of the human eye lens journal December 2010
Shielding design calculation for SPring-8 beamlines using STAC8 journal May 1998
Shielding calculations for the National Synchrotron Light Source-II experimental beamlines
  • Job, Panakkal K.; Casey, William R.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 698 https://doi.org/10.1016/j.nima.2012.08.043
journal January 2013
The calculation of scattering cross sections for polarized X-rays journal March 1986
X-Ray Interactions: Photoabsorption, Scattering, Transmission, and Reflection at E = 50-30,000 eV, Z = 1-92 journal July 1993
Development of shielding design code for synchrotron radiation beam line journal July 1994
Comparison of synchrotron radiation calculations between analytical codes (STAC8, PHOTON) and Monte Carlo codes (FLUKA, EGS4) journal December 2005
IMD—Software for modeling the optical properties of multilayer films journal January 1998
Dimensions of the human eye relevant to radiation protection (dosimetry) journal March 1975
National Council on Radiation Protection and Measurements Commentary Number 26: Impact of Revised Guidance on Radiation Protection for the Lens of the Eye journal July 2017

Similar Records

Radiation shielding analysis of the small-angle X-ray scattering flight tube end station of APS upgrade project
Journal Article · Thu Oct 22 00:00:00 EDT 2020 · Nuclear Instruments and Methods in Physics Research. Section B, Beam Interactions with Materials and Atoms · OSTI ID:1615745

COMPARISON OF SYNCHROTRON RADIATION CALCULATIONS BETWEEN ANALYTIC CODES (STAC8, PHOTON) AND MONTE CARLO CODES (FLUKA, EGS4)
Technical Report · Mon Jul 12 00:00:00 EDT 2004 · OSTI ID:1615745

Conceptual Design of a Dedicated SAXS Beamline at NSRRC
Journal Article · Fri Jan 19 00:00:00 EST 2007 · AIP Conference Proceedings · OSTI ID:1615745