Thermal comfort evaluated for combinations of energy-efficient personal heating and cooling devices
- Univ. of California, Berkeley, CA (United States)
Personal comfort systems (PCS) have potential to fulfill building occupants' personal thermal comfort preferences with great efficiency. But to integrate them into building conditioning, there must be a broader selection of PCS devices available. Design guidance and standards are needed to assure that such devices provide high levels of comfort effectiveness and energy efficiency. This study addresses these needs. A suite of minimum-power PCS devices was built that target body parts significant to alliesthesia—a heated shoe insole, heated/cooled wristpad, small deskfan, and heated/cooled chair. They were tested in a climate chamber under cool and warm conditions using both thermal-manikin and human-subjects. Their efficiency at physically heating/cooling the body is high; the combined suite has a coefficient of performance (COP) of 3.6 for cooling and 0.88 for heating. The subjects' whole-body thermal acceptance and thermal comfort perception were improved by the devices in an additive manner; using the combined suite over 80% of people accepted ambient temperatures of 18°C and 29°C. The PCS ‘corrects’ the ambient temperature towards thermal neutrality by as much as 6.5 K cooling and 3.6 K heating, overcoming building occupants' typical interpersonal thermal differences and making possible large HVAC energy savings in buildings. The idea of temperature corrective power can be the basis of standards for PCS.
- Research Organization:
- University of California, Berkeley, CA (United States)
- Sponsoring Organization:
- USDOE Advanced Research Projects Agency - Energy (ARPA-E)
- Grant/Contract Number:
- AR0000529
- OSTI ID:
- 1613635
- Alternate ID(s):
- OSTI ID: 1548028
- Journal Information:
- Building and Environment, Vol. 143; ISSN 0360-1323
- Publisher:
- ElsevierCopyright Statement
- Country of Publication:
- United States
- Language:
- English
Web of Science
Numerical and experimental investigation of the effect of air conditioning duct on the room temperature distribution and energy efficiency
|
journal | December 2019 |
Experimental comparison of thermal conditions in office rooms: Diffuse ceiling ventilation, chilled beam system, and chilled ceiling combined with mixing ventilation
|
journal | January 2020 |
Implementation of demand-oriented ventilation with adjustable fan network
|
journal | January 2020 |
Similar Records
Micro-Environmental Control System (Final Report)
Experimental Evaluation of the Micro-Environmental Control System in Maintaining Thermal Comfort