skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Modeling the impact of GIC neutral blocking devices on distance protection relay operations for transmission lines

Journal Article · · Electric Power Systems Research

Geomagnetic Induced Current (GIC) blocking devices typically include a capacitor on the neutral grounding path of wye-configured transformers. This type of GIC blocking device was designed as an effective countermeasure to prevent possible damages caused on the power grid by geomagnetic storms, and by the slow-varying component of a high-altitude electromagnetic pulse (HEMP). The insertion of a capacitor in the transformer neutral impedes the establishment of GICs in lines terminated with wye-connected transformer windings. With the presence of a capacitively grounded neutral, however, it becomes important to evaluate that no adverse effects are introduced in the general grid operations. In this context, this study investigates the impact of GIC neutral blocking devices on the functionality of distance protection relays for different values of transformer neutral blocking capacitors, and at different transmission line voltages. This study was conducted with a real-time simulation platform, and the simulations were performed by introducing a phase-to-ground fault at different line locations, and by measuring the apparent impedance at the protection relay location. Finally, the results indicated that, for typical values of capacitance considered for GIC neutral blocking devices, the distance protection relay model operates properly, without requiring a modification of the relay settings.

Research Organization:
Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
Sponsoring Organization:
USDOE
Grant/Contract Number:
AC05-00OR22725
OSTI ID:
1607236
Journal Information:
Electric Power Systems Research, Vol. 180, Issue C; ISSN 0378-7796
Publisher:
ElsevierCopyright Statement
Country of Publication:
United States
Language:
English
Citation Metrics:
Cited by: 4 works
Citation information provided by
Web of Science

Similar Records

GIC mitigation; A neutral blocking/bypass device to prevent the flow of GIC in power systems
Journal Article · Mon Jul 01 00:00:00 EDT 1991 · IEEE Transactions on Power Delivery (Institute of Electrical and Electronics Engineers); (United States) · OSTI ID:1607236

The effects of GIC on protective relaying
Journal Article · Mon Apr 01 00:00:00 EST 1996 · IEEE Transactions on Power Delivery · OSTI ID:1607236

Induction generator modeling and relaying
Thesis/Dissertation · Thu Jan 01 00:00:00 EST 1987 · OSTI ID:1607236