During the RHIC 2003 run, two beam position monitors (BPMs) in each transverse plane in the RHIC blue ring were upgraded with high-capacity mezzanine cards. This upgrade provided these planes with the capability to digitize up to 128 million consecutive turns of RHIC beam, or almost 30 minutes of continuous beam centroid phase space evolution for a single RHIC bunch. This paper describes necessary hardware and software changes and initial system performance. We discuss early uses and results for diagnosis of coherent beam oscillations, turn-by-turn (TBT) acquisition through a RHIC acceleration ramp, and ac-dipole nonlinear dynamics studies.
- Research Organization:
- BROOKHAVEN NATIONAL LABORATORY (US)
- Sponsoring Organization:
- DOE/SC (US)
- DOE Contract Number:
- AC02-98CH10886
- OSTI ID:
- 15006660
- Report Number(s):
- BNL-69614-CP; R&D Project: AD003; KB0202011; TRN: US0400966
- Resource Relation:
- Conference: 2003 PARTICLE ACCELERATOR CONFERENCE, PORTLAND, OR (US), 05/12/2003--05/16/2003; Other Information: PBD: 12 May 2003