Title: Rohm and Haas: Company Uses Knoxville Plant Assessment Results to Develop Best Practices Guidelines and Benchmark for Its Other Sites (Revised)

Technical Report ·
DOI:https://doi.org/10.2172/15003728· OSTI ID:15003728

Rohm and Haas conducted a plant-wide energy assessment at its Knoxville, Tennessee, chemicals manufacturing facility. The assessment identified potential annual energy savings of nearly 47,000 MMBtu in steam and fuel and 11,000 MWh in electricity. Annual cost savings were estimated at almost$1.5 million. After the assessment was replicated in California and Kentucky plants, the companys additional estimated cost savings were$500,000 annually. Additional annual energy savings were about 23,000 MMBtu and 6,000 MWh. The assessments also indicated the plants would reduce nitrous oxide emissions.

Research Organization:
National Renewable Energy Laboratory (NREL), Golden, CO (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC36-99-GO10337
OSTI ID:
15003728
Report Number(s):
DOE/GO-102003-1714
Resource Relation:
Related Information: Supercedes May 2003 version. ; Industrial Technologies Program Chemicals BestPractices Plant-Wide Assessment Case Study (Brochure)
Country of Publication:
United States
Language:
English