skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: A 4 tonne demonstrator for large-scale dual-phase liquid argon time projection chambers

Journal Article · · Journal of Instrumentation
; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; more »; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; « less

A 10 kilo-tonne dual-phase liquid argon TPC is one of the detector options considered for the Deep Underground Neutrino Experiment (DUNE). The detector technology relies on amplification of the ionisation charge in ultra-pure argon vapour and offers several advantages compared to the traditional single-phase liquid argon TPCs. A 4.2 tonne dual-phase liquid argon TPC prototype, the largest of its kind, with an active volume of \three has been constructed and operated at CERN. In this paper we describe in detail the experimental setup and detector components as well as report on the operation experience. We also present the first results on the achieved charge amplification, prompt scintillation and electroluminescence detection, and purity of the liquid argon from analyses of a collected sample of cosmic ray muons.

Research Organization:
Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
Sponsoring Organization:
USDOE Office of Science (SC), High Energy Physics (HEP)
Contributing Organization:
DUNE Collaboration
Grant/Contract Number:
AC02-07CH11359
OSTI ID:
1462731
Report Number(s):
arXiv:1806.03317; FERMILAB-PUB-18-257-ND; 1677274; TRN: US1902210
Journal Information:
Journal of Instrumentation, Vol. 13, Issue 11; ISSN 1748-0221
Publisher:
Institute of Physics (IOP)Copyright Statement
Country of Publication:
United States
Language:
English
Citation Metrics:
Cited by: 21 works
Citation information provided by
Web of Science

References (30)

Design, construction and tests of the ICARUS T600 detector
  • Amerio, S.; Amoruso, S.; Antonello, M.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 527, Issue 3 https://doi.org/10.1016/j.nima.2004.02.044
journal July 2004
Analysis of a large sample of neutrino-induced muons with the ArgoNeuT detector journal October 2012
Underground neutrino detectors for particle and astroparticle Science: The Giant Liquid Argon Charge Imaging ExpeRiment (GLACIER) journal June 2009
Construction and operation of a double phase LAr Large Electron Multiplier Time Projection Chamber
  • Badertscher, A.; Knecht, L.; Laffranchi, M.
  • 2008 IEEE Nuclear Science Symposium and Medical Imaging conference (2008 NSS/MIC), 2008 IEEE Nuclear Science Symposium Conference Record https://doi.org/10.1109/NSSMIC.2008.4774662
conference October 2008
Operation of a double-phase pure argon Large Electron Multiplier Time Projection Chamber: Comparison of single and double phase operation
  • Badertscher, A.; Knecht, L.; Laffranchi, M.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 617, Issue 1-3 https://doi.org/10.1016/j.nima.2009.10.011
journal May 2010
First operation of a double phase LAr Large Electron Multiplier Time Projection Chamber with a 2D projective readout anode
  • Badertscher, A.; Curioni, A.; Knecht, L.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 641, Issue 1 https://doi.org/10.1016/j.nima.2011.02.100
journal June 2011
First operation and performance of a 200 lt double phase LAr LEM-TPC with a 40 × 76 cm 2 readout journal April 2013
Long-term operation of a double phase LAr LEM Time Projection Chamber with a simplified anode and extraction-grid design journal March 2014
Secondary scintillation yield in pure argon journal October 2008
Fluorescence of Tetraphenyl-Butadiene in the Vacuum Ultraviolet journal January 1973
Test of a Liquid Argon TPC in a magnetic field and investigation of high temperature superconductors in liquid argon and nitrogen journal July 2011
Performance study of the effective gain of the double phase liquid Argon LEM Time Projection Chamber journal March 2015
Charge Sensitive Amplifier (CSA) in cold gas of Liquid Argon (LAr) Time Projection Chamber (TPC) journal January 2011
Commissioning of the ArDM experiment at the Canfranc underground laboratory: first steps towards a tonne-scale liquid argon time projection chamber for Dark Matter searches journal March 2017
ArDM: first results from underground commissioning journal September 2013
ArDM: a ton-scale liquid Argon experiment for direct detection of Dark Matter in the Universe journal May 2006
First test of a high voltage feedthrough for liquid Argon TPCs connected to a 300 kV power supply journal March 2017
Performance and Results of the LBNE 35 Ton Membrane Cryostat Prototype journal January 2015
Erratum: Scintillation time dependence and pulse shape discrimination in liquid argon [Phys. Rev. C 78 , 035801 (2008)] journal March 2010
Study on TPB as wavelength shifter for the new ICARUS T600 light collection system in the SBN program journal January 2018
A model for the Global Quantum Efficiency for a TPB-based wavelength-shifting system used with photomultiplier tubes in liquid argon in MicroBooNE journal February 2018
A Novel Cosmic Ray Tagger System for Liquid Argon TPC Neutrino Detectors journal February 2017
Multi-channel front-end board for SiPM readout journal October 2016
Evidence for a triplet state of the self-trapped exciton states in liquid argon, krypton and xenon journal June 1978
Effect of ionization density on the time dependence of luminescence from liquid argon and xenon journal May 1983
Scintillation light from cosmic-ray muons in liquid argon journal May 2016
Evidence of delayed light emission of tetraphenyl-butadiene excited by liquid-argon scintillation light journal March 2015
Gaseous and dual-phase time projection chambers for imaging rare processes
  • González-Díaz, Diego; Monrabal, Francesc; Murphy, Sebastien
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 878 https://doi.org/10.1016/j.nima.2017.09.024
journal January 2018
Measurement of longitudinal electron diffusion in liquid argon
  • Li, Yichen; Tsang, Thomas; Thorn, Craig
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 816 https://doi.org/10.1016/j.nima.2016.01.094
journal April 2016
Study of electron recombination in liquid argon with the ICARUS TPC
  • Amoruso, S.; Antonello, M.; Aprili, P.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 523, Issue 3 https://doi.org/10.1016/j.nima.2003.11.423
journal May 2004

Cited By (1)

Status of DUNE journal January 2019

Similar Records

Performance study of a 3×1×1 m3 dual phase liquid Argon Time Projection Chamber exposed to cosmic rays
Journal Article · Thu Aug 26 00:00:00 EDT 2021 · Journal of Instrumentation · OSTI ID:1462731

Studies on the scintillation light detection in the ProtoDUNE Dual Phase liquid-argon TPC and its capability for the supernova trigger in DUNE
Thesis/Dissertation · Wed Dec 15 00:00:00 EST 2021 · OSTI ID:1462731

Scintillation light detection in the 6-m drift-length ProtoDUNE Dual Phase liquid argon TPC
Journal Article · Sat Jul 16 00:00:00 EDT 2022 · European Physical Journal. C, Particles and Fields (Online) · OSTI ID:1462731