Source detection at 100 meter standoff with a time-encoded imaging system
Journal Article
·
· Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Sandia National Lab. (SNL-CA), Livermore, CA (United States)
- Sandia National Lab. (SNL-CA), Livermore, CA (United States); Univ. of Michigan, Ann Arbor, MI (United States)
- Sandia National Lab. (SNL-CA), Livermore, CA (United States); Univ. of Tennessee, Knoxville, TN (United States)
Here, we present the design, characterization, and testing of a laboratory prototype radiological search and localization system. The system, based on time-encoded imaging, uses the attenuation signature of neutrons in time, induced by the geometrical layout and motion of the system. We have demonstrated the ability to detect a ~1 mCi252 Cf radiological source at 100 m standoff with 90% detection efficiency and 10% false positives against background in 12 min. As a result, this same detection efficiency is met at 15 s for a 40 m standoff, and 1.2 s for a 20 m standoff.
- Research Organization:
- Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
- Sponsoring Organization:
- USDOE National Nuclear Security Administration (NNSA), Office of Defense Nuclear Nonproliferation
- Grant/Contract Number:
- AC04-94AL85000; NA0003525
- OSTI ID:
- 1406359
- Alternate ID(s):
- OSTI ID: 1549284
- Report Number(s):
- SAND-2017-10692J; PII: S0168900217310227; TRN: US1703262
- Journal Information:
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 877; ISSN 0168-9002
- Publisher:
- ElsevierCopyright Statement
- Country of Publication:
- United States
- Language:
- English
Cited by: 7 works
Citation information provided by
Web of Science
Web of Science
Similar Records
SORIS - A standoff radiation imaging system
Standoff detection of turbulent chemical mixture plumes using a swept external cavity quantum cascade laser
Optimized performance for neutron interrogation to detect SNM
Journal Article
·
Sat Oct 01 00:00:00 EDT 2011
· Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, 652(1):5-9
·
OSTI ID:1406359
+6 more
Standoff detection of turbulent chemical mixture plumes using a swept external cavity quantum cascade laser
Journal Article
·
Mon Aug 21 00:00:00 EDT 2017
· Optical Engineering
·
OSTI ID:1406359
Optimized performance for neutron interrogation to detect SNM
Technical Report
·
Wed Feb 14 00:00:00 EST 2007
·
OSTI ID:1406359
+10 more